Filter Results By:

Products

Applications

Manufacturers

Recording Systems

Equipment designed to make an automatic record of output from test equipment.


Showing results: 181 - 195 of 210 items found.

  • Wireless Data Logger

    Ajinkya Electronic Systems

    IM2100 Series Scanners are useful for scanning parameters like temperature, flow, humidity, pressure etc and indicate them in a multiplexed manner. These scanners show the values one after the other in preprogrammed time interval called scan time. Options like PC communication, alarm relays are available. Scanners can communicate with SCADA software and are suitable for Data Acquisition system where local recording is not required.

  • Digital Storage Oscilloscope

    SDS6000A - SIGLENT Technologies

    The SDS6000A series employs Siglent’s SPO technology with a maximum waveform capture rate of up to 170,000 wfm/ s (normal mode, up to 750,000 wfm/s in Sequence mode), 256-level intensity grading display function plus a color temperature display mode. It also employs an innovative digital trigger system with high sensitivity and low jitter. The trigger system supports multiple powerful triggering modes including serial bus triggering. Tools such as History waveform recording, Search and Navigate functions, Mask Test, Bode Plot, Power Analysis, and Eye/Jitter Analysis allow for extended waveform records to be captured, stored, and analyzed. An impressive array of measurement and math capabilities, options for a 25 MHz arbitrary waveform generator, as well as serial decoding are also features of the SDS6000A Digital Oscilloscope.

  • Automatic High Voltage Wire Harness Testers

    MK Test Systems Ltd.

    Automatic high voltage wire harness testers are used in a variety of industries, such as aerospace and defence through to rail, and are used to test any equipment which contains a high number of electrical wires, or active components ensuring these pass specified test criteria at the sub-assembly and final stages of construction. These systems ensure the wiring and components are 100% compliant and undamaged, recording every test measurement and aiding diagnosis of detected faults.

  • Test Stand Auxiliary Power Plant Stationary System

    ViTec Co. Ltd

    The automated control system based on the measuring system implements the following main functions:control and management of the units of the test stand;measurement and recording of parameters related to the APU tests and characterizing the operation of the test bed units;blocking the start and emergency stop of the APU in accordance with the specified conditions;control of calibration / calibration processes of metering channels and calculation of metrological characteristics in accordance with verification methods;formation of text test reports;the formation of graphic protocols;the formation of an archive of test reports, graphical protocols for changing parameters during testing, and calibration / calibration protocols for measuring channels.

  • Plus Super Phosphor Oscilloscopes

    SDS2000X - SIGLENT Technologies

    The SDS2000X Plus series employs SIGLENT’s SPO technology with a maximum waveform capture rate of up to 120,000 wfm/s (normal mode, up to 500,000 wfm/s in Sequence mode), 256-level intensity grading display function plus a color temperature display mode. It also employs an innovative digital trigger system with high sensitivity and low jitter. The trigger system supports multiple powerful triggering modes including serial bus triggering. History waveform recording, Sequence acquisition, Search and Navigate functions allow for extended waveform records to be captured, stored, and analyzed. An impressive array of measurement and math capabilities, options for a 50 MHz waveform generator, as well as serial decoding, mask test, bode plot, and power analysis are also features of the SDS2000X Plus. A 10-bit acquisition mode helps to satisfy applications which require more than 8-bit resolution.

  • Digitizer

    751Family - CAEN S.p.A.

    The 751 is a family of CAEN Waveform Digitizer able to perform basic waveform recording and run online advanced algorithms (DPP) of charge integration and pulse shape discrimination with constant fraction timing and zero-length encoding. Data is read by a Flash ADC, 10-bit resolution and 1GS/s sampling rate (2GS/s using half of the channels in DES mode), which is well suited for fast signals as the ones coming from fast organic, inorganic and liquid scintillators coupled to PMTs or Silicon Photomultipliers, Diamond detectors and others. The acquisitioncan be channel independent and it is possible to make coincidence/ anti-coincidence logic among diferent channels and external veto/ gating. Multiple boards can be synchronized to build up complex systems.

  • Micro Melting Point Instrument

    DRK8026 - Shandong Drick Instruments Co., Ltd.

    Determine crystal melting point of the substance to make sure its purity. Mainly used for determining the meltingpoints of medicine,dyestuff,spice and other organic crystal compounds.Using photoelectric automatic detection, Dot matrix LCD display picture technology, digital keyboard input, and has the initial melting, final weld automatic display,automatic recording of melting curve, automatically determine the melting point of the mean value function. The temperature system uses highly linear platinum resistance as detection elements and PID regulation technology, improved the melting point’s precision and reliability. The instrument establishes communication with PC through the USB or RS232, printing or saving the curve and it uses capillary Pharmacopoeia as sample tube.

  • ARINC 429 PC/104+ Interface Module

    PC104p-429 - Avionics Interface Technologies

    Four or Eight Software Programmable Tx/Rx Channels -Programmable High/Low Speed Operation - Concurrent operation of all Tx/Rx Channels at high data rates - Rate-oriented Label Transmission - Label Selective Trigger for Capture/Filtering - Real-Time Recording & Post Analysis of Multiple Channels - ANSI Application Interface supporting C++, C#, and .net Development - Device Driver Support: Windows, Linux, VxWorks, and other operating systems - Conformal coating available - Designed for extended temperature operations - PC/104+ specification v2.2 compliant

  • Laboratory EM current meter / water level and wave height meter

    JFE Advantech Co., Ltd.

    ACM2-RS and ACM3-RS are 2-D and 3-D electro-magnetic current meters for laboratory experiments. The models provide digital output, a high-speed sampling rate and insusceptibility to electro-magnetic noise. ACH-600RS is a highly sensitive capacitance water level meters. With the new system, a maximum of four different sensors can be connected to the compact interface unit, enabling simultaneous recording on a personal computer. Additionally, the system can provide analog output as well as necessary. While conventional water level and wave height meters cannot be used near velocity sensors, our instrument can be as near as 5 cm without increasing noise, due to its special isolated circuit. The result is an innovative system that is capable of achieving highly accurate data.

  • Ultra High Productivity Solution

    Universal Encoder 3 - Seismic Source Co.

    *Compatibility - UE3 is 100% compatible with the Force 3 system. Boards can be used as spares for the Force 3 system*Reference Flexibility - Multiple Digital and Analog References*GPS Discipline - GPS timing and assures starts on even sample boundaries for all continuous recording systems*Multiple Radio Support - UE3 can connect simultaneously to 4 High Speed TDMA radios. These multiple high speed radios assure reliable and efficient communication to all of the vibrator units used in High Production Vibroseis Mode*Digital Radio Support - UE3 supports the latest Digital Radios*Analog Radio Support - UE3 also supports legacy analog radios*Ethernet Radios Support - The UE3 includes support for low-power VHF-Ethernet radios. These radios have good speed and work well in many applications*Digital Radio Sims - Digital Radio Similarities are now available for UE3 and Force 3 or VibPro HD vibrator controllers*External USB Port - Use USB thumb drive to offload data from remotely operated UE3 units

  • Digitizer

    740 Family - CAEN S.p.A.

    The 740 is a high channel density CAEN Waveform Digitizer family able to perform basic waveform recording and run online advanced algorithms (DPP) of charge integration. Both the elevate number of channels per board (32 for Desktop and NIM form factor, 64 for VME) and the DPP algorithm make the board a digital replacement of a traditional QDC. Data is read by a Flash ADC, 12-bit resolution and 62.5 MS/s sampling rate, which is well suited for mid-slow signals as the ones coming from inorganic scintillators coupled to PMTs, gaseous detectors and others. Sampling rate can be further reduced using the decimation feature. The acquisition can be channel independent and externally vetoed/gated. Multiple boards can be synchronized to build up complex systems.

  • RF signal distribution

    SpectralNet™ - Avtec Systems, Inc.

    RT Logic’s SpectralNet eliminates the physical distance limitations in RF signal distribution, enabling the optimization of ground infrastructure to improve flexibility, reliability and reduce costs. SpectralNet is the first product to digitize and transport RF spectrum over IP networks in a way that preserves both frequency and timing characteristics, and then faithfully reconstructing the original RF signals to enable processing, recording or retransmission at another location. SpectralNet provides advanced networking tools to ensure reliable transport of digitized RF across lossy public and private IP networks. SpectralNet brings analog RF data to the IP network world, unleashing the power of virtualization and centralization of ground architectures for satellite and range ground systems, teleports, UAV and missile ranges, and ISR data processing.

  • Dual Vapor Gravimetric Sorption Analyzer

    DVS Resolution - Surface Measurement Systems

    DVS Resolution’s key feature is the combined ability to precisely control and measure temperature and relative humidity while recording the highest resolution changes in mass. DVS Resolution uses a dry carrier gas typically nitrogen or compressed air for its operation. Digital mass flow controllers regulate flows of dry and saturated gases. Relative humidity is generated by precisely mixing dry and saturated gas flows in desired flow ratios which produce expected relative humidity. In a typical experiment a known concentration of water vapor is delivered over a sample placed inside the sample pan connected to the Surface Measurement Systems Ultrabalance™ measuring realtime mass changes caused by sorption or desorption of water molecules. Prior to sorption measurements, the sample can be in-situ preheated/dried at temperatures of up to 300oC.

  • Digital Melting Point Apparatus

    DRK8011 - Shandong Drick Instruments Co., Ltd.

    DRK8011 Digital melting point apparatus is fully in line with ‘humanize’ of the design concept, using photoelectric automatic detection, dot matrix image LCD technology, digital keyboard input, each measuring one sample, measure three times the average of the melting point of the automatic strike, and has a melting, melting end automatically, melting curve automatic recording function. Temperature system uses high inearity make platinum resistance sensing element, the use of PID regulationtechnology to improve theaccuracy and reliability of the melting point, and with integrated electronic circuits to achieve rapid "starting temperature" setting and eight stalls to choose from linear "heating rate" Automatic Control. Instrument to establish communication with the PC via USB, save or print the graph, the instrument can be directly connected with the RS232 mini-printers, print graphs. The instrument uses Pharmacopoeia as a sample capillary tube.

  • HDD-8261, 4 TB, 6-Drive, PXI Data Storage Module

    784192-01 - NI

    4 TB, 6-Drive, PXI Data Storage Module - The HDD‑8261 in-chassis PXI Express high-speed data storage module features an onboard PCI Express SATA controller. The module fits into a PXI Express chassis, and it occupies only three PXI slots. With the HDD‑8261, you can choose between hard-disk drives (HDDs) or solid-state drives (SSDs) for increased ruggedness. It is ideal for field testing or signal recording applications. You can use this module to not only stream high-speed data, but also to easily move data between multiple test setups or supplement the PXI system controller’s storage capacity.

Get Help